FLINTEC
Remote Display FRD-57
Datum
Code
Rev
Seite
27.09.04
FRD-57
2 von 3
Connection FRD- 57
The connection should be conducted with an 2-wire shielded cable.
The shield should be connected at the FT-Indicator .
Fig.1 shows the terminal block, Jumper and Dip switch at the remote indicator.
Fig. 1
ST2
20mA current loop
RS232
SGND
SHLD
Tx
+Tx
-Tx
Spannungsversorgung 10VAC
RS485
A
B
JP2
S1
1
2
3
4
JP1
Settings of the Dip Switch ( S1 )
Baudrate 1200 2400 9600 19200
Dip SW (on)
xxxxxxx 1 2 1,2
Data E,7,1 N,8,1 E,8,1
xxxxxxx
Dip SW (on)
xxxxxxx 3 4 3,4
Jumper Settings ( JP1 , JP 2 )
RS-232 20mA cur.Loop RS-485
Fig. 2