MCS-08 Technical Manual, Rev. 1.04 December 2012 Page 32 of 52
Next Dword defines the usage of this Dword
Description of 2
nd
Dword (R)
*Register address for MCS-08AD [1]: 4
th
…5
th
Dword,
MCS-08AD [2]: 6
th
…7
th
Dword,
MCS-08AD [3]: 8
th
…9
th
Dword,
MCS-08AD [4]: 10
th
…11
th
Dword,
MCS-08AD [5]: 12
th
…13
th
Dword,
MCS-08AD [6]: 14
th
…15
th
Dword,
MCS-08AD [7]: 16
th
…17
th
Dword definitions are same as 2
nd
– 3
rd
Dwords
3
rd
, 5
th
, 7
th
, 9
th
, 11
th
, 13
th
, 15
th
, 17
th
Dword Description
Start span calibration. First load 2
nd
Dword with test weight,
then apply this command with New CMD.
Operation mode selection. First load 2
nd
Dword with selected
value, then apply this command with New CMD.
0 = Count mode unipolar, 1 = Count mode bipolar, 2 Force
mode unipolar, 3 = Force mode bipolar, 4 = Weight mode
unipolar
mV operation in Count Mode. First load 2
nd
Dword with
selected value, then apply this command with New CMD.
0 = 5mV, 1 = 10mV, 2 = 15 mV, 3 = 18mV
Digital filter. First load 2
nd
Dword with selected value, then
apply this command with New CMD.
Filter values: 0 = Fast,….., 9 = Slow
Description of 2
nd
Dword (R)
Indicated weight (floating point type)
Gross weight (floating point type)
Tare weight (floating point type)
Increased resolution for indicated weight
Apply command (of the commands listed in this table)